[{"data":1,"prerenderedAt":170},["ShallowReactive",2],{"page:protocols:en":3},{"id":4,"title":5,"body":6,"description":162,"extension":163,"meta":164,"navigation":165,"path":166,"productVersion":167,"routeKey":12,"seo":168,"stem":12,"__hash__":169},"content_en\u002Fprotocols.md","Protocols and integrations",{"type":7,"value":8,"toc":153},"minimark",[9,14,18,23,52,58,62,78,83,87,98,103,107,127,130,134,138,141],[10,11,13],"h1",{"id":12},"protocols","Protocols",[15,16,17],"p",{},"2WinScada connects to field devices through a channel, device and tag hierarchy. License scope and your project's compatibility are separate questions. We do not give a general compatibility statement for specific device models; we assess your devices with you before the quote.",[19,20,22],"h2",{"id":21},"standard-protocols","Standard protocols",[24,25,26,34,40,46],"ul",{},[27,28,29,33],"li",{},[30,31,32],"strong",{},"Modbus:"," Modbus TCP, Modbus over a serial line and Modbus through a serial-to-Ethernet gateway. 2WinScada works as the client (master).",[27,35,36,39],{},[30,37,38],{},"Siemens S7:"," Communication over Ethernet (ISO-on-TCP) with the S7-200, S7-200 Smart, LOGO! 0BA8, S7-300, S7-400, S7-1200 and S7-1500 families. DB, input, output, memory, timer and counter areas are accessed by absolute address. On the S7-1200 and S7-1500, PUT\u002FGET access must be allowed in the PLC and optimized block access must be off for the DBs used.",[27,41,42,45],{},[30,43,44],{},"BACnet:"," Works as a BACnet\u002FIP (IPv4) client. The Present Value of objects is read; writing is done on Analog, Binary and Multi-state objects. Devices on the network can be discovered. BACnet MS\u002FTP and COV subscriptions are not supported.",[27,47,48,51],{},[30,49,50],{},"MTConnect:"," Data is read over HTTP through an MTConnect agent. MTConnect is read-only.",[15,53,54,57],{},[30,55,56],{},"Package:"," Modbus and Siemens S7 are included in every package. BACnet\u002FIP and MTConnect are included in Standard and Professional. Starter includes two of OPC UA, BACnet\u002FIP and MTConnect (choice; by default BACnet\u002FIP and MTConnect); the third can be added to your quote.",[19,59,61],{"id":60},"opc-ua","OPC UA",[24,63,64,72,75],{},[27,65,66,67,71],{},"OPC UA client: connects to ",[68,69,70],"code",{},"opc.tcp:\u002F\u002F"," endpoints anonymously or with a username and password.",[27,73,74],{},"Signed and encrypted connections, browsing the server's address space, bulk tag import and reading through subscriptions.",[27,76,77],{},"Certificate and IssuedToken user identities are not supported.",[15,79,80,82],{},[30,81,56],{}," Included in Professional. In Standard, operation is included; managing OPC UA definitions with your own team can be added to your quote. Starter includes two of OPC UA, BACnet\u002FIP and MTConnect; OPC UA can be one of the two.",[19,84,86],{"id":85},"ethernetip","EtherNet\u002FIP",[24,88,89,92,95],{},[27,90,91],{},"Explicit messaging and cyclic (implicit) I\u002FO.",[27,93,94],{},"Access to generic CIP objects, and symbolic tag access on Rockwell\u002FAllen-Bradley Logix and Omron NX\u002FNJ controllers.",[27,96,97],{},"CIP Safety, CIP Motion and CIP Security are not supported. Do not use EtherNet\u002FIP communication in place of a safety function.",[15,99,100,102],{},[30,101,56],{}," Included in Standard and Professional. In Starter it can be added to your quote.",[19,104,106],{"id":105},"mqtt-rest-and-database-odbc","MQTT, REST and database (ODBC)",[24,108,109,115,121],{},[27,110,111,114],{},[30,112,113],{},"MQTT:"," 2WinScada subscribes to topics on an MQTT broker and writes incoming values to tags.",[27,116,117,120],{},[30,118,119],{},"REST:"," With REST Client, 2WinScada pulls data from an external system's HTTP API at set intervals. With REST Server, external systems send data to 2WinScada with a device key.",[27,122,123,126],{},[30,124,125],{},"Database (ODBC):"," Values are read from and written to address–value tables in another system's database. A suitable ODBC driver must be installed on the server.",[15,128,129],{},"Before the quote, we check compatibility with your broker, API or database for your project.",[15,131,132,102],{},[30,133,56],{},[19,135,137],{"id":136},"how-we-check-compatibility","How we check compatibility",[15,139,140],{},"Select the protocols you use in the form and describe your needs. In the meeting we go through device models, addressing and the network layout with you.",[15,142,143,148,149],{},[144,145,147],"a",{"href":146},"\u002Fen\u002Fdemo-quote","Request a demo"," · ",[144,150,152],{"href":151},"\u002Fen\u002Fdemo-quote?type=quote","Request a quote",{"title":154,"searchDepth":155,"depth":155,"links":156},"",2,[157,158,159,160,161],{"id":21,"depth":155,"text":22},{"id":60,"depth":155,"text":61},{"id":85,"depth":155,"text":86},{"id":105,"depth":155,"text":106},{"id":136,"depth":155,"text":137},"Modbus, Siemens S7, BACnet\u002FIP, MTConnect, OPC UA, EtherNet\u002FIP, MQTT, REST and database (ODBC): scope in 2WinScada and packages.","md",{},true,"\u002Fprotocols","2.11.0",{"title":5,"description":162},"VjKQFpiD8AxS3-pudc7qf6Xl6igDlMnAzmqHP2flNGg",1793018227148]